Designed for portable, wall-mounted, and stationary industrial charging applications, this page presents the Intelligent Industrial Charger family with detailed technical parameters, charger architecture, and application guidance — all in the same visual rhythm as your Home page.
✔ PORTABLE ✔ WALL-MOUNTED ✔ STATIONARY ✔ CE / IEC 62477
Engineering superior uptime, safety, and connectivity for high-stakes industrial mobility.
One platform, multiple forms. Choose from Portable, Wall-Mounted, or Stationary configurations to fit your specific facility layout.
Multi-protocol support including CAN, RS485, RS232, WiFi, and optional 4G/LTE.
Comprehensive safety logic, including Over/Under Voltage, Over-Current, Short-Circuit, Over-Temp, and Reverse Polarity protection.
Choose the ideal form factor for your facility’s unique operational needs.
Power Range: 2.4 kW | 3 kW | 6.6 kW
Best For: Field service, flexible fleet maintenance, and small-site industrial charging where mobility is critical.
Key Advantage: Lightweight and rugged design for easy transport and rapid deployment anywhere.
Power Range: 3 kW | 6.6 kW
Best For: Fixed-position charging, crowded warehouses, and clean-room environments.
Key Advantage: Streamlined installation that maximizes floor space while keeping cables organized and safe.
Power Range: 9 kW – 40 kW (Including 10/12/15/18/20/24/30 kW models)
Best For: Large-scale logistics hubs, heavy-duty forklift fleets, and mission-critical high-output projects.
Key Advantage: Industrial-grade durability designed for continuous, high-performance charging cycles.
Industry-leading charging standards engineered for reliability and precision.
Up to 95% Peak Efficiency for Stationary systems and ≥ 92% for Portable/Wall-mounted units.
Voltage Accuracy: ±0.5% + 0.2%FS
Current Accuracy: Up to ±1% + 0.2%FS
Time Accuracy: ≤ ±10s / 24h
High-performance Intelligent Forced Air Cooling.
Explore the full performance data for our 2.4kW to 6.6kW portable charger family. Engineered for high-mobility industrial environments where reliability and compact design are critical.
| Parameter | TPO6201 | TPO6202 | TPO6203 | TPO6204 |
|---|---|---|---|---|
| Output Power | 3 kW | 3 kW | 3 kW | 3 kW |
| Rated Output Voltage (Vdc) | 24 V | 48 V | 80 V | 120 V |
| Output Voltage Range (Vdc) | 5 ~ 30 V | 5 ~ 60 V | 5 ~ 100 V | 10 ~ 132 V |
| Maximum Output Current | 100 A | 50 A | 30 A | 25 A |
| Rated Input Current | 15 A | |||
| Input Voltage (Vac) | 110 / 230 V (90 ~ 264 V), L + N + PE | |||
| Input Frequency Range | 47 ~ 63 Hz | |||
| Peak conversion efficiency | ≥ 92 % | |||
| Load Regulation | ±5 % @10 ~ 100 %load | |||
| Voltage Accuracy | ±0.5 % + 0.2 %FS | |||
| Current Accuracy | ±1 % + 0.2 %FS | |||
| Time Accuracy | ≤ ±10 s/24h | |||
| BMS Charging | DC 12 / 24 V 3 Amax (Optional) | |||
| Protection Function | OVP overvoltage protection, OCP overcurrent protection, OPP over power protection, OTP overtemperature protection, UVP undervoltage protection, SCP short circuit protection, RCP reverse connection protection | |||
| Connector Type | Anderson Connector / National Standard Charging Gun / REMA / Customized | |||
| Communication Method | RS485, RS232, CAN, Wifi, 4G (Optional) | |||
| MTBF | 80000 h | |||
| Cooling | Forced Air Cooling | |||
| Working & Storage Temperature And Humidity | Operating temperature: -20~70℃, intelligent derating when ambient temperature exceeds 50℃, 20-90% RH non-condensing. Storage temperature: -40~85℃, 10-95% RH non-condensing | |||
| Structure Size (mm) | 410 * 175 * 180 (L * W * H) | |||
| Display Status | LED / LCD / Touchscreen (Optional) | |||
| Safety Regulations | Designed to comply with CE and IEC 62477 standards | |||
| Parameter | TPO6222 | TPO6807 | TPO6808 | TPO6809 |
|---|---|---|---|---|
| Output Power | 2.4 kW | 6.6 kW | 6.6 kW | 6.6 kW |
| Rated Output Voltage (Vdc) | 30 V | 24 V | 48 V | 80 V |
| Output Voltage Range (Vdc) | 10 ~ 30 V | 5 ~ 30 V | 5 ~ 60 V | 5 ~ 100 V |
| Maximum Output Current | 80 A | 200 A | 110 A | 60 A |
| Rated Input Current | 12 A | 30 A | ||
| Input Voltage (Vac) | 110 / 220 V (90 ~ 295 V) L + N + PE | 110 / 230 V (90 ~ 264 V), L + N + PE | ||
| Input Frequency Range | 47 ~ 63 Hz | |||
| Peak conversion efficiency | ≥ 92 % | |||
| Load Regulation | ±5 % @10 ~ 100 %load | |||
| Voltage Accuracy | ±0.5 % + 0.2 %FS | |||
| Current Accuracy | ±1 % + 0.2 %FS | |||
| Time Accuracy | ≤ ±10 s/24h | |||
| BMS Charging | DC 12 / 2.5 A (3A Max) | DC 12 / 24 V 3 Amax (Optional) | ||
| Protection Function | OVP overvoltage protection, OCP overcurrent protection, OPP over power protection, OTP overtemperature protection, UVP undervoltage protection, SCP short circuit protection, RCP reverse connection protection | |||
| Connector Type | REMA | Anderson Connector / National Standard Charging Gun / REMA / Customized | ||
| Communication Method | RS485, CAN (Optional) | RS485, RS232, CAN, Wifi, 4G (Optional) | ||
| MTBF | 80000 h | |||
| Cooling | Forced Air Cooling | |||
| Working & Storage Temperature And Humidity | Operating temperature: -20~70℃, intelligent derating when ambient temperature exceeds 50℃, 20-90% RH non-condensing. Storage temperature: -40~85℃, 10-95% RH non-condensing | |||
| Structure Size (mm) | 283.5*195.5*102.5 (L*W*H) | 535 * 220 * 400 (L * W * H) | ||
| Display Status | / | LED / LCD / Touchscreen (Optional) | ||
| Safety Regulations | Designed to comply with CE and IEC 62477 standards | |||
Engineered for fixed-position charging where floor space is at a premium. Explore the detailed performance data for our 3kW and 6.6kW wall-mounted industrial chargers.
| Parameter | TPO6201 | TPO6202 | TPO6203 | TPO6204 | TPO6807 | TPO6808 | TPO6809 |
|---|---|---|---|---|---|---|---|
| Output Power | 3 kW | 6.6 kW | |||||
| Rated Output Voltage (Vdc) | 24 V | 48 V | 80 V | 120 V | 24 V | 48 V | 80 V |
| Output Voltage Range (Vdc) | 5 ~ 30 V | 5 ~ 60 V | 5 ~ 100 V | 10 ~ 132 V | 5 ~ 33 V | 5 ~ 60 V | 5 ~ 100 V |
| Maximum Output Current | 100 A | 50 A | 30 A | 25 A | 200 A | 110 A | 60 A |
| Rated Input Current | 15 A | 30 A | |||||
| Input Voltage (Vac) | 110 / 230 V (90 ~ 264 V), L + N + PE | ||||||
| Input Frequency Range | 47 ~ 63 Hz | ||||||
| Peak conversion efficiency | 92 % | ||||||
| Load Regulation | ±5 % @10 ~ 100 %load | ||||||
| Voltage Accuracy | ±0.5 % + 0.2 %FS | ||||||
| Current Accuracy | ±1 % + 0.2 %FS | ||||||
| Time Accuracy | ≤ ±10 s/24h | ||||||
| BMS Charging | DC 12 / 24 V 3 Amax (Optional) | ||||||
| Protection Function | OVP overvoltage protection, OCP overcurrent protection, OPP over power protection, OTP overtemperature protection, UVP undervoltage protection, SCP short circuit protection, RCP reverse connection protection | ||||||
| Connector Type | Anderson Connector / National Standard Charging Gun / REMA / Customized | ||||||
| Communication Method | RS485, RS232, CAN, Wifi, 4G (Optional) | ||||||
| MTBF | 80000 h | ||||||
| Cooling | Forced Air Cooling | ||||||
| Working & Storage Temperature And Humidity | Operating temperature: -20~70℃, intelligent derating when ambient temperature exceeds 50℃, 20-90% RH non-condensing. Storage temperature: -40~85℃, 10-95% RH non-condensing. | ||||||
| Structure Size (mm) | 410 * 175 * 180 (L * W * H) | 535 * 220 * 400 (L * W * H) | |||||
| Display Status | LED / LCD / Touch screen (Optional) | ||||||
| Safety Regulations | Designed to comply with CE and IEC 62477 standards | ||||||
Scaling from 9kW to 40kW, our stationary charger family is engineered for mission-critical industrial infrastructure. Explore the robust performance data for our high-output power models below.
| Parameter | TPO6811 | TPO6812 | TPO6813 | TPO6816 | TPO6818 |
|---|---|---|---|---|---|
| Output Power | 9 kW | 10 kW | 12 kW | 15 kW | 20 kW |
| Rated Output Voltage (Vdc) | 48 V | 80 V | 48 V | 80 V | 80 V |
| Output Voltage Range (Vdc) | 20 ~ 60 V | 30 ~ 100 V | 20 ~ 60 V | 20 ~ 110 V | 20 ~ 110 V |
| Maximum Output Current | 150 A | 100 A | 200 A | 150 A | 200 A |
| Rated Input Current | 15 A | 15 A | 18 A | 24 A | 30 A |
| Input Voltage (Vac) | 380 / 480 V (303 ~ 530 V), 3L + PE | ||||
| Input Frequency Range | 47 ~ 63 Hz | ||||
| Peak conversion efficiency | ≥ 94 % | ||||
| Load Regulation | ±5 % @10 ~ 100 %load | ||||
| Voltage Accuracy | ±0.5 % + 0.2 %FS | ||||
| Current Accuracy | ±1 % + 0.2 %FS | ||||
| Time Accuracy | ≤ ±10 s/24h | ||||
| BMS Charging | DC 12 / 24 V 3 Amax (Optional) | ||||
| Protection Function | OVP overvoltage protection, OCP overcurrent protection, OPP over power protection, OTP overtemperature protection, UVP undervoltage protection, SCP short circuit protection, RCP reverse connection protection | ||||
| Connector Type | Anderson Connector / National Standard Charging Gun / REMA / Customized | ||||
| Communication Method | RS485, RS232, CAN, Wifi, 4G (Optional) | ||||
| MTBF | 80000 h | ||||
| Cooling | Forced Air Cooling | ||||
| Working & Storage Temperature And Humidity | Operating temperature: -20~70℃, intelligent derating when ambient temperature exceeds 50℃, 20-90% RH non-condensing. Storage temperature: -40~85℃, 10-95% RH non-condensing | ||||
| Structure Size (mm) | 535 * 220 * 400 (L * W * H) | ||||
| Display Status | LED / LCD / Touch screen (Optional) | ||||
| Safety Regulations | Designed to comply with CE and IEC 62477 standards | ||||
| Parameter | TPO6811 | TPO6812 | TPO6813 | TPO6816 | TPO6817 | TPO6818 | TPO6822 |
|---|---|---|---|---|---|---|---|
| Output Power | 9 kW | 10 kW | 12 kW | 15 kW | 18 kW | 20 kW | 30 kW |
| Rated Output Voltage (Vdc) | 48 V | 80 V | 48 V | 80 V | 48 V | 80 V | 80 V |
| Output Voltage Range (Vdc) | 20 ~ 60 V | 30 ~ 100 V | 20 ~ 60 V | 30 ~ 100 V | 20 ~ 60 V | 20 ~ 100 V | 20 ~ 100 V |
| Maximum Output Current | 150 A | 100 A | 200 A | 150 A | 300 A | 200 A | 300 A |
| Rated Input Current | 15 A | 15 A | 18 A | 24 A | 30 A | 30 A | 45 A |
| Input Voltage (Vac) | 380 / 480 V (303 ~ 530 V), 3L + PE | ||||||
| Input Frequency Range | 47 ~ 63 Hz | ||||||
| Conversion Efficiency | 95 % | ||||||
| Peak conversion efficiency | ±5 % @10 ~ 100 %load | ||||||
| Voltage Accuracy | ±0.5 % + 0.2 %FS | ||||||
| Current Accuracy | ±1 % + 0.5 %FS | ||||||
| Time Accuracy | ≤ ±10 s/24h | ||||||
| BMS Charging | DC 12 / 24 V (Optional) | ||||||
| Protection Function | OVP overvoltage protection, OCP overcurrent protection, OPP over power protection, OTP overtemperature protection, UVP undervoltage protection, SCP short circuit protection, RCP reverse connection protection | ||||||
| Connector Type | Anderson Connector / National Standard Charging Gun / REMA / Customized | ||||||
| Communication Method | RS485, RS232, CAN, Wifi, 4G (Optional) | ||||||
| Output Gun Count | Single-gun | ||||||
| MTBF | 80000 h | ||||||
| Cooling | Forced Air Cooling | ||||||
| Working & Storage Temperature And Humidity | Operating temperature: -20~70℃, intelligent derating when ambient temperature exceeds 50℃, 20-90% RH non-condensing. Storage temperature: -40~85℃, 10-95% RH non-condensing. | ||||||
| Structure Size (mm) | 600 * 350 * 750 (L * W * H) | ||||||
| Display Status | LED / LCD / Touchscreen (Optional) | ||||||
| Safety Regulations | Designed to comply with CE and IEC 62477 standards | ||||||
| Parameter | TPO6830 | TPO6847 |
|---|---|---|
| Output Power | 24 kW | 40 kW |
| Rated Output Voltage (Vdc) | 48 V | 80 V |
| Output Voltage Range (Vdc) | 10 ~ 60 V | 20 ~ 100 V |
| Maximum Output Current | 200 A single gun, 400 A Double gun | — |
| Rated Input Current | 36 A | 60 A |
| Input Voltage (Vac) | 380 / 480 V (303 ~ 530 V), 3L + PE | |
| Input Frequency Range | 47 ~ 63 Hz | |
| Conversion efficiency | ≥ 95 % | |
| Peak conversion efficiency | ±5 % @10 ~ 100 %load | |
| Voltage Accuracy | ±0.5 % + 0.2 %FS | |
| Current Accuracy | ±1 % + 0.5 %FS | |
| Time Accuracy | ≤ ±10 s/24h | |
| BMS Charging | DC 12 / 24 V 3 Amax (Optional) | |
| Protection Function | OVP overvoltage protection, OCP overcurrent protection, OPP over power protection, OTP overtemperature protection, UVP undervoltage protection, SCP short circuit protection, RCP reverse connection protection | |
| Connector Type | Anderson Connector / National Standard Charging Gun / REMA / Customized | |
| Communication Method | RS485, RS232, CAN, Wifi, 4G (Optional) | |
| Output Gun Count | Dual-gun | |
| MTBF | 80000 h | |
| Cooling | Forced air cooling | |
| Working & Storage Temperature And Humidity | Operating temperature: -20~70℃, intelligent derating when ambient temperature exceeds 50℃, 20-90% RH non-condensing. Storage temperature: -40~85℃, 10-95% RH non-condensing. | |
| Structure Size (mm) | 420 * 440 * 930 (L * W * H) | |
| Display Status | LED / LCD / Touchcreen (Optional) | |
| Safety Regulations | Designed to comply with CE and IEC 62477 standards | |
Application-based content helps buyers understand where Intelligent Industrial Chargers fit best and how the charger family can support different industrial charging scenarios.
Reliable, high-efficiency charging designed for 24/7 automated workflows.
Heavy-duty power tailored for the demanding duty cycles of warehouse and logistics hubs.
Robust charging for custom mobility platforms and specialized industrial equipment.
Tailor-made charging hardware to meet your unique project specifications.
Tell us your charger type, output voltage, current requirement, connector standard, or deployment environment. We will recommend the right model path.