Intelligent Industrial Charger

Designed for portable, wall-mounted, and stationary industrial charging applications, this page presents the Intelligent Industrial Charger family with detailed technical parameters, charger architecture, and application guidance — all in the same visual rhythm as your Home page.

✔ PORTABLE    ✔ WALL-MOUNTED    ✔ STATIONARY    ✔ CE / IEC 62477

The Intelligent Standard for Industrial Charging

Engineering superior uptime, safety, and connectivity for high-stakes industrial mobility.

Versatile Deployment Architecture

One platform, multiple forms. Choose from Portable, Wall-Mounted, or Stationary configurations to fit your specific facility layout.

Advanced Connectivity & Smart Control

Multi-protocol support including CAN, RS485, RS232, WiFi, and optional 4G/LTE.

Mission-Critical Protection & Reliability

Comprehensive safety logic, including Over/Under Voltage, Over-Current, Short-Circuit, Over-Temp, and Reverse Polarity protection.

Intelligent Industrial Charger Portfolio

Choose the ideal form factor for your facility’s unique operational needs.

Portable Series: Mobile Power on Demand

Power Range: 2.4 kW | 3 kW | 6.6 kW
Best For: Field service, flexible fleet maintenance, and small-site industrial charging where mobility is critical.
Key Advantage: Lightweight and rugged design for easy transport and rapid deployment anywhere.

Wall-Mounted Series: Space-Saving Efficiency

Power Range: 3 kW | 6.6 kW
Best For: Fixed-position charging, crowded warehouses, and clean-room environments.
Key Advantage: Streamlined installation that maximizes floor space while keeping cables organized and safe.

Stationary Series: High-Capacity Infrastructure

Power Range: 9 kW – 40 kW (Including 10/12/15/18/20/24/30 kW models)
Best For: Large-scale logistics hubs, heavy-duty forklift fleets, and mission-critical high-output projects.
Key Advantage: Industrial-grade durability designed for continuous, high-performance charging cycles.

Core Technical Performance

Industry-leading charging standards engineered for reliability and precision.

High-Efficiency Conversion

Up to 95% Peak Efficiency for Stationary systems and ≥ 92% for Portable/Wall-mounted units.

Precision Charging Accuracy

Voltage Accuracy: ±0.5% + 0.2%FS
Current Accuracy: Up to ±1% + 0.2%FS
Time Accuracy: ≤ ±10s / 24h

Rugged Environmental Resilience

High-performance Intelligent Forced Air Cooling.

Portable Series: Technical Specifications

Explore the full performance data for our 2.4kW to 6.6kW portable charger family. Engineered for high-mobility industrial environments where reliability and compact design are critical.

ParameterTPO6201TPO6202TPO6203TPO6204
Output Power3 kW3 kW3 kW3 kW
Rated Output Voltage (Vdc)24 V48 V80 V120 V
Output Voltage Range (Vdc)5 ~ 30 V5 ~ 60 V5 ~ 100 V10 ~ 132 V
Maximum Output Current100 A50 A30 A25 A
Rated Input Current15 A
Input Voltage (Vac)110 / 230 V (90 ~ 264 V), L + N + PE
Input Frequency Range47 ~ 63 Hz
Peak conversion efficiency≥ 92 %
Load Regulation±5 % @10 ~ 100 %load
Voltage Accuracy±0.5 % + 0.2 %FS
Current Accuracy±1 % + 0.2 %FS
Time Accuracy≤ ±10 s/24h
BMS ChargingDC 12 / 24 V 3 Amax (Optional)
Protection FunctionOVP overvoltage protection, OCP overcurrent protection, OPP over power protection, OTP overtemperature protection, UVP undervoltage protection, SCP short circuit protection, RCP reverse connection protection
Connector TypeAnderson Connector / National Standard Charging Gun / REMA / Customized
Communication MethodRS485, RS232, CAN, Wifi, 4G (Optional)
MTBF80000 h
CoolingForced Air Cooling
Working & Storage Temperature And HumidityOperating temperature: -20~70℃, intelligent derating when ambient temperature exceeds 50℃, 20-90% RH non-condensing. Storage temperature: -40~85℃, 10-95% RH non-condensing
Structure Size (mm)410 * 175 * 180 (L * W * H)
Display StatusLED / LCD / Touchscreen (Optional)
Safety RegulationsDesigned to comply with CE and IEC 62477 standards
ParameterTPO6222TPO6807TPO6808TPO6809
Output Power2.4 kW6.6 kW6.6 kW6.6 kW
Rated Output Voltage (Vdc)30 V24 V48 V80 V
Output Voltage Range (Vdc)10 ~ 30 V5 ~ 30 V5 ~ 60 V5 ~ 100 V
Maximum Output Current80 A200 A110 A60 A
Rated Input Current12 A30 A
Input Voltage (Vac)110 / 220 V (90 ~ 295 V) L + N + PE110 / 230 V (90 ~ 264 V), L + N + PE
Input Frequency Range47 ~ 63 Hz
Peak conversion efficiency≥ 92 %
Load Regulation±5 % @10 ~ 100 %load
Voltage Accuracy±0.5 % + 0.2 %FS
Current Accuracy±1 % + 0.2 %FS
Time Accuracy≤ ±10 s/24h
BMS ChargingDC 12 / 2.5 A (3A Max)DC 12 / 24 V 3 Amax (Optional)
Protection FunctionOVP overvoltage protection, OCP overcurrent protection, OPP over power protection, OTP overtemperature protection, UVP undervoltage protection, SCP short circuit protection, RCP reverse connection protection
Connector TypeREMAAnderson Connector / National Standard Charging Gun / REMA / Customized
Communication MethodRS485, CAN (Optional)RS485, RS232, CAN, Wifi, 4G (Optional)
MTBF80000 h
CoolingForced Air Cooling
Working & Storage Temperature And HumidityOperating temperature: -20~70℃, intelligent derating when ambient temperature exceeds 50℃, 20-90% RH non-condensing. Storage temperature: -40~85℃, 10-95% RH non-condensing
Structure Size (mm)283.5*195.5*102.5 (L*W*H)535 * 220 * 400 (L * W * H)
Display Status/LED / LCD / Touchscreen (Optional)
Safety RegulationsDesigned to comply with CE and IEC 62477 standards

Wall-Mounted Series: Optimized Technical Specs

Engineered for fixed-position charging where floor space is at a premium. Explore the detailed performance data for our 3kW and 6.6kW wall-mounted industrial chargers.

ParameterTPO6201TPO6202TPO6203TPO6204TPO6807TPO6808TPO6809
Output Power3 kW6.6 kW
Rated Output Voltage (Vdc)24 V48 V80 V120 V24 V48 V80 V
Output Voltage Range (Vdc)5 ~ 30 V5 ~ 60 V5 ~ 100 V10 ~ 132 V5 ~ 33 V5 ~ 60 V5 ~ 100 V
Maximum Output Current100 A50 A30 A25 A200 A110 A60 A
Rated Input Current15 A30 A
Input Voltage (Vac)110 / 230 V (90 ~ 264 V), L + N + PE
Input Frequency Range47 ~ 63 Hz
Peak conversion efficiency92 %
Load Regulation±5 % @10 ~ 100 %load
Voltage Accuracy±0.5 % + 0.2 %FS
Current Accuracy±1 % + 0.2 %FS
Time Accuracy≤ ±10 s/24h
BMS ChargingDC 12 / 24 V 3 Amax (Optional)
Protection FunctionOVP overvoltage protection, OCP overcurrent protection, OPP over power protection, OTP overtemperature protection, UVP undervoltage protection, SCP short circuit protection, RCP reverse connection protection
Connector TypeAnderson Connector / National Standard Charging Gun / REMA / Customized
Communication MethodRS485, RS232, CAN, Wifi, 4G (Optional)
MTBF80000 h
CoolingForced Air Cooling
Working & Storage Temperature And HumidityOperating temperature: -20~70℃, intelligent derating when ambient temperature exceeds 50℃, 20-90% RH non-condensing. Storage temperature: -40~85℃, 10-95% RH non-condensing.
Structure Size (mm)410 * 175 * 180 (L * W * H)535 * 220 * 400 (L * W * H)
Display StatusLED / LCD / Touch screen (Optional)
Safety RegulationsDesigned to comply with CE and IEC 62477 standards

High-Capacity Stationary Series: Technical Specs

Scaling from 9kW to 40kW, our stationary charger family is engineered for mission-critical industrial infrastructure. Explore the robust performance data for our high-output power models below.

ParameterTPO6811TPO6812TPO6813TPO6816TPO6818
Output Power9 kW10 kW12 kW15 kW20 kW
Rated Output Voltage (Vdc)48 V80 V48 V80 V80 V
Output Voltage Range (Vdc)20 ~ 60 V30 ~ 100 V20 ~ 60 V20 ~ 110 V20 ~ 110 V
Maximum Output Current150 A100 A200 A150 A200 A
Rated Input Current15 A15 A18 A24 A30 A
Input Voltage (Vac)380 / 480 V (303 ~ 530 V), 3L + PE
Input Frequency Range47 ~ 63 Hz
Peak conversion efficiency≥ 94 %
Load Regulation±5 % @10 ~ 100 %load
Voltage Accuracy±0.5 % + 0.2 %FS
Current Accuracy±1 % + 0.2 %FS
Time Accuracy≤ ±10 s/24h
BMS ChargingDC 12 / 24 V 3 Amax (Optional)
Protection FunctionOVP overvoltage protection, OCP overcurrent protection, OPP over power protection, OTP overtemperature protection, UVP undervoltage protection, SCP short circuit protection, RCP reverse connection protection
Connector TypeAnderson Connector / National Standard Charging Gun / REMA / Customized
Communication MethodRS485, RS232, CAN, Wifi, 4G (Optional)
MTBF80000 h
CoolingForced Air Cooling
Working & Storage Temperature And HumidityOperating temperature: -20~70℃, intelligent derating when ambient temperature exceeds 50℃, 20-90% RH non-condensing. Storage temperature: -40~85℃, 10-95% RH non-condensing
Structure Size (mm)535 * 220 * 400 (L * W * H)
Display StatusLED / LCD / Touch screen (Optional)
Safety RegulationsDesigned to comply with CE and IEC 62477 standards
ParameterTPO6811TPO6812TPO6813TPO6816TPO6817TPO6818TPO6822
Output Power9 kW10 kW12 kW15 kW18 kW20 kW30 kW
Rated Output Voltage (Vdc)48 V80 V48 V80 V48 V80 V80 V
Output Voltage Range (Vdc)20 ~ 60 V30 ~ 100 V20 ~ 60 V30 ~ 100 V20 ~ 60 V20 ~ 100 V20 ~ 100 V
Maximum Output Current150 A100 A200 A150 A300 A200 A300 A
Rated Input Current15 A15 A18 A24 A30 A30 A45 A
Input Voltage (Vac)380 / 480 V (303 ~ 530 V), 3L + PE
Input Frequency Range47 ~ 63 Hz
Conversion Efficiency95 %
Peak conversion efficiency±5 % @10 ~ 100 %load
Voltage Accuracy±0.5 % + 0.2 %FS
Current Accuracy±1 % + 0.5 %FS
Time Accuracy≤ ±10 s/24h
BMS ChargingDC 12 / 24 V (Optional)
Protection FunctionOVP overvoltage protection, OCP overcurrent protection, OPP over power protection, OTP overtemperature protection, UVP undervoltage protection, SCP short circuit protection, RCP reverse connection protection
Connector TypeAnderson Connector / National Standard Charging Gun / REMA / Customized
Communication MethodRS485, RS232, CAN, Wifi, 4G (Optional)
Output Gun CountSingle-gun
MTBF80000 h
CoolingForced Air Cooling
Working & Storage Temperature And HumidityOperating temperature: -20~70℃, intelligent derating when ambient temperature exceeds 50℃, 20-90% RH non-condensing. Storage temperature: -40~85℃, 10-95% RH non-condensing.
Structure Size (mm)600 * 350 * 750 (L * W * H)
Display StatusLED / LCD / Touchscreen (Optional)
Safety RegulationsDesigned to comply with CE and IEC 62477 standards
ParameterTPO6830TPO6847
Output Power24 kW40 kW
Rated Output Voltage (Vdc)48 V80 V
Output Voltage Range (Vdc)10 ~ 60 V20 ~ 100 V
Maximum Output Current200 A single gun, 400 A Double gun
Rated Input Current36 A60 A
Input Voltage (Vac)380 / 480 V (303 ~ 530 V), 3L + PE
Input Frequency Range47 ~ 63 Hz
Conversion efficiency≥ 95 %
Peak conversion efficiency±5 % @10 ~ 100 %load
Voltage Accuracy±0.5 % + 0.2 %FS
Current Accuracy±1 % + 0.5 %FS
Time Accuracy≤ ±10 s/24h
BMS ChargingDC 12 / 24 V 3 Amax (Optional)
Protection FunctionOVP overvoltage protection, OCP overcurrent protection, OPP over power protection, OTP overtemperature protection, UVP undervoltage protection, SCP short circuit protection, RCP reverse connection protection
Connector TypeAnderson Connector / National Standard Charging Gun / REMA / Customized
Communication MethodRS485, RS232, CAN, Wifi, 4G (Optional)
Output Gun CountDual-gun
MTBF80000 h
CoolingForced air cooling
Working & Storage Temperature And HumidityOperating temperature: -20~70℃, intelligent derating when ambient temperature exceeds 50℃, 20-90% RH non-condensing. Storage temperature: -40~85℃, 10-95% RH non-condensing.
Structure Size (mm)420 * 440 * 930 (L * W * H)
Display StatusLED / LCD / Touchcreen (Optional)
Safety RegulationsDesigned to comply with CE and IEC 62477 standards

Typical Application Areas

Application-based content helps buyers understand where Intelligent Industrial Chargers fit best and how the charger family can support different industrial charging scenarios.

Autonomous Logistics (AGV / AMR)

Reliable, high-efficiency charging designed for 24/7 automated workflows.

Forklift & Material Handling Fleets

Heavy-duty power tailored for the demanding duty cycles of warehouse and logistics hubs.

Specialized Industrial Mobility

Robust charging for custom mobility platforms and specialized industrial equipment.

Custom OEM / ODM Solutions

Tailor-made charging hardware to meet your unique project specifications.

Need the Right Intelligent Industrial Charger for Your Project?

Tell us your charger type, output voltage, current requirement, connector standard, or deployment environment. We will recommend the right model path.